Commercial Plan Review apply to Condominiums,
triplexes, multi-family apartments,
businesses of all types, mixed-use structures,
and other miscellaneous categories
such as fire, sprinklers, alarms, kitchen hoods,
and dumpster enclosures.
Commercial Plan Review
Site Plan
- Location
- Dimensions
- Site Elevations
- Flood Zone
Survey
- Trees
- Easements
- Cross Section
Building Plans
- Current FBC, NFPA, FFPC, and NEC Code references
- Building Construction Type
- Scope of work
- Scaled floor plan with room labels and dimensions
- Termite protection notes(if required)
- Florida Product Approvals (if required)
- Exterior building elevation views (if required)
- Structural detail design criteria (if required)
- Wind speed/pressure
- Roof and floor live/dead loads
- Foundation plan, section, and details (if required)
- Floor and roof framing plans, including section/details (if required)
- Exterior and interior wall sections (if required)
- Height and area calculations
- Life safety (egress) plan
- Proposed occupancy and use
Mechanical Plans
- Project address or legal description
- Current FBC (Mechanical) reference.
- Floor plan showing layout of the following, as applicable
- Proposed mechanical system.
- Duct work and vents.
- Equipment and appliances.
- Heating and cooling loads (performance specifications).
Electrical Plans
- Project address or legal description
- Current NEC reference
- Floor plan showing layout of the following, as applicable
- Proposed electrical system
- Associated fixtures, devices, and equipment
- Load Calculations
- Electrical Panel schedule and Riser Diagram
Plumbing Plans
- Project address or legal description
- Current FBC (Plumbing) reference
- Floor plan showing layout of the following, as applicable
- Proposed pimping, fixtures, materials
Energy Calculations
Threshold Documents (if applicable)
Site Plan
- Location
- Dimensions
- Site Elevations
- Flood Zone
- Easements
Building Plans
- Current FBC, NFPA, FFPC, and NEC Code references
- Building Construction Type
- Scope of work
- Scaled floor plan with room labels and dimensions
- Termite protection notes(if required)
- Florida Product Approvals (if required)
- Exterior building elevation views (if required)
- Structural detail design criteria (if required)
- Wind speed/pressure
- Roof and floor live/dead loads
- Foundation plan, section, and details (if required)
- Floor and roof framing plans, including section/details (if required)
- Exterior and interior wall sections (if required)
- Height and area calculations
- Life safety (egress) plan
- Proposed occupancy and use
Mechanical Plans
- Project address or legal description
- Current FBC (Mechanical) reference.
- Floor plan showing layout of the following, as applicable
- Proposed mechanical system.
- Duct work and vents.
- Equipment and appliances.
- Heating and cooling loads (performance specifications).
Electrical Plans
- Project address or legal description
- Current NEC reference
- Floor plan showing layout of the following, as applicable
- Proposed electrical system
- Associated fixtures, devices, and equipment
- Load Calculations
- Electrical Panel schedule and Riser Diagram
Plumbing Plans
- Project address or legal description
- Current FBC (Plumbing) reference
- Floor plan showing layout of the following, as applicable
- Proposed piping, fixtures, materials
Energy Calculations
Threshold Documents (if applicable)
Document Review
- Site Plan
- Show canopy location / dimensions
- Building Plans
- Structural components / details
- Elevations
Document Review
- Site Plan
- Show canopy location / dimensions
- Building Plans
- Structural components / details
- Elevations
+Electrical
Document Review
- Site Plan
- Showing existing and proposed power connections
- Building Plans
- Power Demon Plan (if applicable)
- Power & Rise Diagram
- Panel Schedule
- Electrical Details
Document Review
- Site Plan or Survey
- Generator location
- Surrounding Trees
- Property Lines
- Building Plans
- Concrete Pad Plan
- Electrical Plan (Riser)
- Sizing Report
- Generator Product Data Sheets
Site Plan
- Location
- Dimensions
- Site Elevations
- Flood Zone
Survey
- Trees
- Easements
- Cross Section
Building Plans
- Current FBC, NFPA, FFPC, and NEC Code references
- Building Construction Type
- Scope of work
- Scaled floor plan with room labels and dimensions
- Termite protection notes(if required)
- Florida Product Approvals (if required)
- Exterior building elevation views (if required)
- Structural detail design criteria (if required)
- Wind speed/pressure
- Roof and floor live/dead loads
- Foundation plan, section, and details (if required)
- Floor and roof framing plans, including section/details (if required)
- Exterior and interior wall sections (if required)
- Height and area calculations
- Life safety (egress) plan
- Proposed occupancy and use
Mechanical Plans
- Project address or legal description
- Current FBC (Mechanical) reference.
- Floor plan showing layout of the following, as applicable
- Proposed mechanical system.
- Duct work and vents.
- Equipment and appliances.
- Heating and cooling loads (performance specifications).
Electrical Plans
- Project address or legal description
- Current NEC reference
- Floor plan showing layout of the following, as applicable
- Proposed electrical system
- Associated fixtures, devices, and equipment
- Load Calculations
- Electrical Panel schedule and Riser Diagram
Plumbing Plans
- Project address or legal description
- Current FBC (Plumbing) reference
- Floor plan showing layout of the following, as applicable
- Proposed pumping, fixtures, materials
Energy Calculations
Threshold Documents (if applicable)
Document Review
- Site Plan
- Location of parking lot
- Proposed Landscape
- Site demo plan (if applicable)
- Grading & Erosion Control
- Standard Construction Details
- Site Lighting Plan (if applicable)
- Schedules
- Riser
+ Perimeter Wall
Site Plan
- Property lines
- Location and dimensions
- Site Elevations
- Trees
- Flood Zone
- Easements
- Cross Section
Building Plans
- Current FBC, NFPA, FFPC, and NEC Code references
- Scope of work
- Structural detail design criteria
- Wall height detail
Site Plan
- Project address or legal description
- Location and dimensions of proposed photovoltaic (PV) system.
- On-site structures, easements (public and private)
- Trees (when required)
- Location, species, and sizes of all trees within 20’ of construction area.
- Tree barricade locations and details.
- Tree mitigation table
Building Plan
- Project address or legal description
- Current Florida Building Code reference
- Structural detail design criteria
- Mounting details
Electrical Plans
- Project address or legal description
- Current NEC reference
- PV array configuration
- Electrical details
- Load calculations
- Site Plan
- Proposed sign location with dimensions to property lines
- Standard Construction Details
- Building Plan
- Elevations
- Sign Specifications including sign area calculations
- Design wind loads report
- Electrical connection information (if applicable)
- Foundation plans for free-standing attachments to the building